GSA-CC1 & GSA-CC2
Signal Module
The Signal Module is used to connect, upon command from the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. Models are available with one or two power inputs. These may be either polarized 24 Vdc to operate audible and visual signal appliances, or 25 and 70Vrms to operate audio evacuation speakers and firefighter’s telephones. The actual function of this module is determined by the “personality code” selected by the installer. A total of three personalities are available.
Overview
GSA-CC1/MCC1 Single Input Signal Modules and GSA-CC2/
MCC2 Dual Input Signal Modules are part of Kidde's Signature
Series system. They are intelligent analog addressable devices
used for connecting, upon command from the loop controller,
supervised Class B signal or telephone circuits to their respective
power inputs. The power inputs may be polarized 24 Vdc to
operate audible and visible signal appliances or 25 and 70 VRMS
to operate audio evacuation speakers and firefighter’s telephones.
The actual operation of the GSA-CC1/MCC1 and GSA-CC2/
MCC2 is determined by the “personality code” selected by the
installer. It is downloaded to the module from the Signature loop
controller during system configuration.
The GSA-CC1 and GSA-CC2 mount to standard North
American two-gang electrical boxes, making them ideal for
locations where only one module is required. Separate I/O and
data loop connections are made to each module.
Standard Features
• Single and Dual input (riser) select
Use for connecting supervised 24 Vdc Audible/Visible signal
circuits, or 25 and 70 VRMS Audio Evacuation and Telephone
circuits to their power inputs.
• Ring-tone generator
When configured for telephone circuits, the GSA-CC1
generates its own ring-tone signal eliminating the need for a
separate ring-tone circuit.
• Plug-in (UIO) or standard 2-gang mount
UIO versions allow quick installation where multiple modules
are required. The 2-gang mount version is ideal for remote
locations that require a single module.
• Automatic device mapping
Signature modules transmit information to the loop controller
regarding their circuit locations with respect to other Signature
devices on the wire loop.
• Electronic addressing
Programmable addresses are downloaded from the loop
controller, a PC, or the SIGA-PRO Signature Program/Service
Tool; there are no switches or dials to set.
• Intelligent device with microprocessor
All decisions are made at the module to allow lower
communication speed with substantially improved control panel
response time and less sensitivity to line noise and loop wiring
properties; twisted or shielded wire is not required.
• Ground fault detection by address
Detects ground faults right down to the device level.