KI-OSCD
Intelligent Fire Detectors with Integrated CO Sensor
The KI series combine an integrated CO sensor with either Smoke, Heat or by itself to suit installation flexibility.
Overview
The Kidde Intelligent Optica Series KI-OSCD smoke detector
brings advanced optical (photoelectric) sensing technology to a
practical design that increases effi ciency, saves installation time,
cuts costs, and extends life safety and property protection
capabilities. Continuous self-diagnostics ensure reliability
over the long-haul, while environmental compensation helps
reduce maintenance costs.
The KI-OSCD provides a combination of optical detection for
the early detection of smoke, with the added element of carbon
monoxide sensing. The result is a detector that pulls double duty:
continually monitoring the environment for signs of fi re, as well as
its invisible yet deadly companion, carbon monoxide.
Like all Kidde Intelligent Optica Series detectors, the KI-OSCD is
an intelligent device that gathers analog information from multiple
optical sensors, converting this data into digital signals. Utilizing
dual optical wavelengths combined with multiple detection angles,
the KI-OSCD differentiates particles that are not representative
of actual smoke. Particle data is input into digital fi lters which
feed a series of ratios removing signal patterns that are typical
of nuisance sources, thus reducing unwanted alarms. To make
an alarm decision, the detector’s on-board microprocessor
measures and analyzes all optical sensor readings and compares
this information to preprogrammed settings. The detector also
analyzes the smoke sensor independently from the CO sensor to
determine whether to initiate a fi re alarm, a life safety CO alarm,
or both.
Standard Features
• Multi-criteria optical smoke sensing technology
• Integrates advanced optical smoke with life safety carbon
monoxide detection
• Wide 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) smoke obscuration
• Integrated nuisance rejection reducing unwanted alarms from
general cooking particulates
• Sensor Markings Provide Easy Testing Identifi cation
• Listed to UL 268 7th edition
• Uses existing wiring
• Automatic device mapping
• Ground fault detection by module
• Up To 250 Total Kidde Intelligent Addresses Per Loop
• Two levels of environmental compensation
• Two levels of dirty detector warning
• Twenty pre-alarm settings
• Five sensitivity settings
• Non-volatile memory
• Electronic addressing
• Automatic day/night sensitivity adjustment
• Bicolor (green/red) status LED
• Standard, relay, fault isolator, and audible mounting bases
Note: Some features described here may not be supported
by all control systems. Check your control panel’s Installation